Eroare SMART (CurrentPendingSector) detectată pe gazdă (Administrarea sistemului, Linux, Ubuntu, Ubuntu 16.04, Smart, Smartctl)

user2353938 a intrebat.

Smart raportează următoarea eroare în fiecare zi pe unul dintre SSD-urile serverului meu din centrul de date:

This message was generated by the smartd daemon running on:

   host name:  x
   DNS domain: x

The following warning/error was logged by the smartd daemon:

Device: /dev/sda [SAT], 1 Currently unreadable (pending) sectors

Device info:
INTEL SSDSC2BB480G7, S/N:PHDV701605XT480BGN, WWN:5-5cd2e4-14d60bdf9, FW:N2010101, 480 GB

For details see host's SYSLOG.

You can also use the smartctl utility for further investigation.
The original message about this issue was sent at Tue Feb  6 18:43:41 2018 EST
Another message will be sent in 24 hours if the problem persists.

Syslog, nu prezintă informații suplimentare.

Am citit în altă parte că trebuie să efectuez un test inteligent extins, apoi să scriu în sectorul specificat în rezultatele testului pentru a forța unitatea să îl marcheze ca fiind un sector defect și să îl realoce.

Am efectuat un test prelungit:

sudo smartctl -t long /dev/sda1

Dar ieșirea din sudo smartctl -a /dev/sda1 spune că testul s-a finalizat fără erori?

smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.4.98-2-pve] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     INTEL SSDSC2BB480G7
Serial Number:    PHDV701605XT480BGN
LU WWN Device Id: 5 5cd2e4 14d60bdf9
Firmware Version: N2010101
User Capacity:    480,103,981,056 bytes [480 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-3 T13/2161-D revision 5
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Feb 21 04:58:20 2018 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (   72) seconds.
Offline data collection
capabilities:                    (0x79) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (   2) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0032   100   100   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       8753
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       11
170 Unknown_Attribute       0x0033   100   100   010    Pre-fail  Always       -       0
171 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
174 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       9
175 Program_Fail_Count_Chip 0x0033   100   100   010    Pre-fail  Always       -       270807480494
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0033   100   100   090    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   070   064   000    Old_age   Always       -       30 (Min/Max 16/37)
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       9
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       30
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       1
199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age   Always       -       0
225 Unknown_SSD_Attribute   0x0032   100   100   000    Old_age   Always       -       415161
226 Unknown_SSD_Attribute   0x0032   100   100   000    Old_age   Always       -       1126
227 Unknown_SSD_Attribute   0x0032   100   100   000    Old_age   Always       -       51
228 Power-off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       525179
232 Available_Reservd_Space 0x0033   100   100   010    Pre-fail  Always       -       0
233 Media_Wearout_Indicator 0x0032   099   099   000    Old_age   Always       -       0
234 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
241 Total_LBAs_Written      0x0032   100   100   000    Old_age   Always       -       415161
242 Total_LBAs_Read         0x0032   100   100   000    Old_age   Always       -       433149
243 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       979238

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      8753         -
# 2  Extended offline    Completed without error       00%      8752         -
# 3  Extended offline    Completed without error       00%      8464         -
# 4  Short offline       Completed without error       00%       888         -
# 5  Short offline       Completed without error       00%       886         -
# 6  Short offline       Completed without error       00%       885         -
# 7  Short offline       Completed without error       00%         0         -
# 8  Short offline       Completed without error       00%         0         -
# 9  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Există într-adevăr o problemă și, dacă da, cum se face un diagnostic corect?

2 răspunsuri
linuxbuild

Doar 1 singur sector în așteptare nu este o problemă pentru o unitate. Doar ignorați-l până când crește semnificativ.

Deși puteți încerca să o reparați folosind următoarele instrucțiuni (mai întâi datele de rezervă!): https://github.com/smartmontools/smartmontools/blob/master/www/BadBlockHowTo.txt

De asemenea, puteți compara raportul S.M.A.R.T. al unității dvs. cu altele în acest depozit de rapoarte S.M.A.R.T..

Comentarii

  • Nu am crezut că este o problemă serioasă, dar S.M.A.R.T. îmi trimite e-mailuri în fiecare zi despre asta! Problema cu instrucțiunile pe care le-ați specificat este că acestea presupun că un test SMART îmi va spune LBA – dar toate testele mele spun „Completat fără erori”. –  > Por user2353938.
Baruch Even

Marea întrebare este dacă acel sector are date care vă interesează, încercați să citiți fișierele de date și vedeți dacă lipsește ceva.

În orice caz, pentru a evita ca acest mesaj de eroare să se repete, va trebui să suprascrieți datele pentru ca unitatea să ignore acest lucru. De asemenea, ar trebui să fie posibilă și tăierea blocului, dacă acesta nu are altă utilizare. Puteți încerca să efectuați un fstrim pe sistemul de fișiere pentru a șterge acest lucru.

Testul SMART lung efectuează un test aleatoriu al suportului și nu este un test complet, astfel încât ar putea reuși chiar dacă există o eroare și mai ales dacă aceasta este o eroare recuperabilă, deoarece producătorul nu ar dori ca o singură eroare în așteptare să vă determine să solicitați RMA pentru unitatea de disc.